| Availability: | |
|---|---|
TR0225-LBH5
TR
Product Features
* Highly insulated between the primary and secondary side.
* Small size ,light weight.
* No insertion loss ,low power consumption.
* Wide detection range.
Product Application
Used in electric power, industrial automation, machinery, automotive, home appliances an other industries and fields.
Technical Parameter
| Specification | 6A/0.625V | 15A/0.625V | 25A/0.625V | Unit | |
|---|---|---|---|---|---|
| IPN | Primary Rated Input Current | 6 | 15 | 25 | A |
| IP | Primary Current Measurement Range | 0-18 | 0-45 | 0-75 | A |
| VSN | Secondary rated output voltage | 2.5±0.625 | V | ||
| VC | The Power Supply Voltage | +5V(±5%) | V | ||
| IC | Current Consumption | <20 | mA | ||
| Vd | Insulation Voltage | Between primary and secondary circuits:2.5kV/50Hz/1min | |||
| εL | Linearity | <0.1 | %FS | ||
| X | Precision | TA=25℃:≤±0.5 | % | ||
| V0 | Offset Voltage | TA=25℃:≤±15 | mV | ||
| VOM | Magnetic Offset Voltage | IP =0 after 3*IPN:≤±10 | mV | ||
| VOT | Offset voltage temperature drift | IP=0 TA=-40-+80℃:≤±0.1 | mV/℃ | ||
| Tr | Response time | <500 | nS | ||
| f | Bandwidth(-1dB) | DC-200 | kHz | ||
| TA | Working Temperature | -40-+80 | ℃ | ||
| TS | Storage Temperature | -45-+85 | ℃ | ||
Shape and Installation Dimensions

Circuit link Diagram

Note:
Installation Precautions
The sensor should be wired correctly, otherwise it may damage the internal components of the sensor.
When the sensor is soldered to the circuit board, it needs to be soldered with a low-temperature soldering iron, and the time should not be too long, and secondly, the pins should not be squeezed by a large amount, otherwise the internal connection may be opened.
Product Features
* Highly insulated between the primary and secondary side.
* Small size ,light weight.
* No insertion loss ,low power consumption.
* Wide detection range.
Product Application
Used in electric power, industrial automation, machinery, automotive, home appliances an other industries and fields.
Technical Parameter
| Specification | 6A/0.625V | 15A/0.625V | 25A/0.625V | Unit | |
|---|---|---|---|---|---|
| IPN | Primary Rated Input Current | 6 | 15 | 25 | A |
| IP | Primary Current Measurement Range | 0-18 | 0-45 | 0-75 | A |
| VSN | Secondary rated output voltage | 2.5±0.625 | V | ||
| VC | The Power Supply Voltage | +5V(±5%) | V | ||
| IC | Current Consumption | <20 | mA | ||
| Vd | Insulation Voltage | Between primary and secondary circuits:2.5kV/50Hz/1min | |||
| εL | Linearity | <0.1 | %FS | ||
| X | Precision | TA=25℃:≤±0.5 | % | ||
| V0 | Offset Voltage | TA=25℃:≤±15 | mV | ||
| VOM | Magnetic Offset Voltage | IP =0 after 3*IPN:≤±10 | mV | ||
| VOT | Offset voltage temperature drift | IP=0 TA=-40-+80℃:≤±0.1 | mV/℃ | ||
| Tr | Response time | <500 | nS | ||
| f | Bandwidth(-1dB) | DC-200 | kHz | ||
| TA | Working Temperature | -40-+80 | ℃ | ||
| TS | Storage Temperature | -45-+85 | ℃ | ||
Shape and Installation Dimensions

Circuit link Diagram

Note:
Installation Precautions
The sensor should be wired correctly, otherwise it may damage the internal components of the sensor.
When the sensor is soldered to the circuit board, it needs to be soldered with a low-temperature soldering iron, and the time should not be too long, and secondly, the pins should not be squeezed by a large amount, otherwise the internal connection may be opened.
Smart Grid Energy Metering: Uses, Applications, Challenges Addressed, and Key Considerations
The Role of Hall Effect Current Sensors in Monitoring Railway Systems
Why Zero-Flux Leakage Current Sensors Are Ideal for Sensitive Leakage Monitoring Systems
Can An AC/DC Current Sensor Improve VFD Speed Control And Automated Systems?
How A Current Sensor Protects Transformer Grounding & Arrester Insulation