Measurement Range: 0.1~10mA, accuracy error: <5%
Action Current: 50A–20kA (8/20μs)
Impulse Current: 100kA (4/10μs)
Applicable Voltage: 10kV–1000kV
Communication Methods: 485 & 4G wireless for remote monitoring
Power Supply: Solar energy or external power supply options
Operating Temperature: -25°C to +70°C
Protection Level: IP65, suitable for harsh environments
Easy Installation: Quick and simple setup with reliable performance
Anti-Interference: Strong resistance to environmental interference
| Availability: | |
|---|---|
TR-ICM-10
TR
* Lightning arrester leakage current, third harmonic current, action times monitoring.
* Data recording, self-diagnosis, intelligent duplex.
* Easy to install.
* Wireless passive.
* Convenient configuration and selection.
* Good anti-interference performance.
Lightning damage is one of the main factors affecting the safe operation of power grids and factories and mines. The proportion of distribution line tripping caused by lightning strikes in total distribution network faults exceeds 60%.Once damaged by lightning strikes, it will directly affect the safe and reliable operation of the power grid and cause unforeseen serious consequences.At the same time, due to the large number and wide distribution of lightning arresters (MOAs), it brings huge daily operation and maintenance, power outage maintenance, and fault handling manpower and economic pressure. Therefore, our company has developed an online monitoring system for lightning arresters, which is applied to the online monitoring of lightning arresters in various occasions.
Measuring Range | 0.1~10mA, accuracy error: <5% |
Action Current (8/20μs) | 50A-20kA |
Impulse Current (4/10μs) | 100kA |
Applicable Voltage | 10kV-1000kV |
Operating Temperature | -25℃-+70℃ |
Protection Level | IP65 |
Communication Methods | 485, 4G |
Power Supply Mode | Solar energy or external power supply |
* Lightning arrester leakage current, third harmonic current, action times monitoring.
* Data recording, self-diagnosis, intelligent duplex.
* Easy to install.
* Wireless passive.
* Convenient configuration and selection.
* Good anti-interference performance.
Lightning damage is one of the main factors affecting the safe operation of power grids and factories and mines. The proportion of distribution line tripping caused by lightning strikes in total distribution network faults exceeds 60%.Once damaged by lightning strikes, it will directly affect the safe and reliable operation of the power grid and cause unforeseen serious consequences.At the same time, due to the large number and wide distribution of lightning arresters (MOAs), it brings huge daily operation and maintenance, power outage maintenance, and fault handling manpower and economic pressure. Therefore, our company has developed an online monitoring system for lightning arresters, which is applied to the online monitoring of lightning arresters in various occasions.
Measuring Range | 0.1~10mA, accuracy error: <5% |
Action Current (8/20μs) | 50A-20kA |
Impulse Current (4/10μs) | 100kA |
Applicable Voltage | 10kV-1000kV |
Operating Temperature | -25℃-+70℃ |
Protection Level | IP65 |
Communication Methods | 485, 4G |
Power Supply Mode | Solar energy or external power supply |