| Availability: | |
|---|---|
Product Features
* Separare structuram, facile ad institutionem ac facilem operari.
* Core ferrea dividi potest, praecisio alta est, et ambitus magneticus parvus est.
* Mensurae currentis, vigilantia et tutela linearum et armorum.
* Fenestrae internae magnae sunt et per fibulas, retinacula vel busbarta transire possunt.
Product Applicationem
Discidium nucleum CTs communiter adhibentur in audito energiae, magna vigilantia, potentia analysis qualitas, et automatio industrialis. Multe adoptantur in aedificiis commercialibus, centris, officinis, ac renovationibus systematis energiae renovandae ob facultatem mensurae currentis non praepotentis faciendi.
Download Location Sheet
Morbi condimentum
Morbi laoreet |
Symbolum |
Indicis |
Rated Input Current |
In |
100A-5000A |
Rated Output Current |
Io |
1A, 5A . |
Rated Load |
RL |
1VA-30VA |
Sagaciter Classis |
ρ |
0.5, 1.0, 1.5 classis |
Brevis-terminus Scelerisque Current |
. |
20×In |
sustinere intentione |
Vd |
3000V AC/1min |
Nulla Resistentia |
. |
≥1000MΩ/500V AC |
Operatio Temperature |
Ta |
-25℃-+75℃ |
Environment Umor |
. |
≤85% |
Operatio Frequency |
f* |
50-60Hz |
Typicam valorem et dimensionem
Type |
Specification |
Rated Load(VA) |
Dimensiones (mm) |
Perforatio Location(mm) |
|||||
0,5 classis |
1.0 classis |
1.5 classis |
W | H | D | A | E | ||
TRDP-30*20 |
100A/5A |
- |
- |
1.5 |
90 | 114 | 40 | 22 | 32 |
150A/5A |
- |
- |
2 |
||||||
200A/5A |
- |
1.5 |
2.5 |
||||||
250A/5A |
- |
1.5 |
3.75 |
||||||
300A/5A |
1.5 |
3.75 |
5 |
||||||
400A/5A |
2.5 |
5 |
10 |
||||||
TRDP-60*40 |
200A/5A |
- |
1.5 |
2.5 |
114 | 140 | 36 | 42 | 62 |
300A/5A |
1.5 |
2.5 |
2 |
||||||
400A/5A |
1.5 |
2.5 |
2 |
||||||
500A/5A |
2.5 |
5 |
15 |
||||||
600A/5A |
2.5 |
5 |
17.5 |
||||||
750A/5A |
2.5 |
5 |
18 |
||||||
800A/5A |
2.5 |
7.5 |
18 |
||||||
1000A/5A |
5 |
10 |
20 |
||||||
TRDP-80*50 |
250A/5A |
1 |
1.5 |
3.75 |
122 | 160 | 40 | 52 | 82 |
300A/5A |
1.5 |
2.5 |
5 |
||||||
400A/5A |
1.5 |
2.5 |
5 |
||||||
500A/5A |
2.5 |
5 |
15 |
||||||
600A/5A |
2.5 |
5 |
17.5 |
||||||
750A/5A |
2.5 |
5 |
18 |
||||||
800A/5A |
2.5 |
7.5 |
18 |
||||||
1000A/5A |
5 |
10 |
20 |
||||||
TRDP-80*80 |
250A/5A |
1 |
2 |
4 |
144 | 160 | 36 | 82 | 82 |
300A/5A |
1.5 |
2.5 |
5 |
||||||
400A/5A |
1.5 |
2.5 |
5 |
||||||
500A/5A |
2.5 |
5 |
15 |
||||||
600A/5A |
2.5 |
5 |
17.5 |
||||||
750A/5A |
2.5 |
5 |
18 |
||||||
800A/5A |
2.5 |
7.5 |
18 |
||||||
1000A/5A |
5 |
10 |
20 |
||||||
Type |
Specification |
Rated Load(VA) |
Dimensiones (mm) | Perforatio Location(mm) | |||||
0,5 classis |
1.0 classis |
1.5 classis |
W |
H | D | A | E | ||
TRDP-100*50 |
500A/5A |
2.5 |
5 |
15 |
144 | 190 | 48 | 52 | 102 |
600A/5A |
2.5 |
5 |
17.5 |
||||||
750A/5A |
2.5 |
5 |
18 |
||||||
800A/5A |
2.5 |
7.5 |
18 |
||||||
1000A/5A |
5 |
10 |
20 |
||||||
1200A/5A |
5 |
12.5 |
24 |
||||||
1250A/5A |
7.5 |
15 |
28 |
||||||
1500A/5A |
7.5 |
17 |
30 |
||||||
TRDP-120*80 |
500A/5A |
- |
4 |
12.5 |
152 | 200 | 40 | 82 | 122 |
600A/5A |
- |
5 |
15 |
||||||
750A/5A |
2.5 |
6 |
17.5 |
||||||
800A/5A |
2.5 |
7.5 |
18 |
||||||
1000A/5A |
5 |
10 |
20 |
||||||
1200A/5A |
5 |
12.5 |
24 |
||||||
1250A/5A |
7.5 |
15 |
28 |
||||||
1500A/5A |
7.5 |
17 |
30 |
||||||
| 1000A/5A | 10 |
15 |
20 |
||||||
| TRDP-140*60 | 1500A/5A | 15 | 20 | 25 | 164 | 234 | 52 | 62 | 122 |
| 2000A/5A | 15 | 20 | 25 | ||||||
| 2500A/5A | 15 | 20 | 25 | ||||||
| 3000A/5A | 20 | 25 | 30 | ||||||
| 4000A/5A | 20 | 25 | 30 | ||||||
| 5000A/5A | 20 | 25 | 30 | ||||||
| TRDP-160*80 | 1000A/5A | 10 |
15 | 20 | 184 | 254 | 52 | 82 | 162 |
| 1500A/5A | 15 | 20 | 25 | ||||||
| 2000A/5A | 15 | 20 |
25 | ||||||
| 2500A/5A | 15 | 20 | 25 | ||||||
| 3000A/5A | 20 | 25 | 30 | ||||||
| 4000A/5A | 20 | 25 | 30 | ||||||
| 5000A/5A | 20 | 25 | 30 | ||||||
Dimensiones


Installation Precuations
* Priusquam apertam commutator venam instituat, metro electrico (vel alio artificio mensurans) bis coniungi debet ut transformator secundarius apertus non sit.
* Pone omnia aperta currenti transformers connexa cum filis secundariis in situ et institutionem exspecta.
* Si funis primus busbarus in situ est, institutionem mentiri potest; Si primus busbarus est vectis aeneus, viva operatio relative altam gradum proficiendi ad operator requirit et bonas mensuras tutelae velit.
* Cum transformator insertis, res alienae ut immunditiae et pulvis incidere in superficies nuclei ferrei non debent, ne immutantis afficiat.