This product is no longer available

Split-core Punture&Power Harverster Flexible Rogowski Coil

Product Description

Product Features

*  Split-core structure, easy to install on site and easy to operate. Quick and easy installation or removal without disconnecting the primary cable under test, effective for safe and easy current testing.

*  Flexible structure design, can detect the current of irregular primary conductor.

*  Low output voltage, high linearity, wide frequency range, no saturation (without integrator).

*  The secondary output adopts shielded wire, and the length can be customized according to customer requirements.


Product Application

Measurement of high current AC signals (such as short-circuit current); measurement of pulse signals with high peak values (such as lightning current); analysis of harmonic current signals; current measurement of electric welding machines (such as resistance welding); measurement of irregular conductor currents (eg: rail current measurement); instrument measurement, clamp meter transformers (eg: measuring conductors with irregular dimensions).


Product Parameters

Electric performance

Working Temperature

-40℃~+70℃

Relative Humidity

≤90%

Voltage Level

0.4/0.66/0.72kV

Accuracy Class

5%(without integrator)

Rated Input Current

10~2000A

Phase Error

≤60'(45Hz~65Hz)

Linear Range

5%~120%

Response Bandwidth

1Hz~1MHz

Auxiliary Integrator Power Supply

5~15V DC

Insulation Strenth

1000MΩ/500V/min

Mechanical structure

Shell

PC Flame Retardant Grade 94-V0

Output Mode

Three-core Shielded Cable

Skeleton and Quilt

Silicone Rubber

Puncture Needle

Stainless Steel"304"

Current Output

Blue Wire - Yellow Line

Power Output

Red Wire


Typical Value and Dimensions

Product Model No.

Rated Input

Rated Output

Precision Class

Dimensions(mm)

Φ1

Φ2

L

W

H

BNWKLC-50R

1000A

50mV
100mV

0.5
1.0

50

8

42

33

88

BNWKLC-100R

4000A

100

10

42

33

88


Output Lead Description:

1. The input end is a cable through the core (P1 → P2).

2. The output end is led out by a three core shielded wire.

3. Red represents the voltage measurement terminal.

4. Blue and yellow are secondary voltage signal outputs.

5. Define the polarity correspondence between "P1" and the blue line as the end with the same name (*).


Installation Precautions

*  When the transformer is powered on, you must wear insulating gloves, and your hands must not directly touch the red core of the shielded wire.

*  Do not use if the output leads are damaged. Our company is not responsible for any safety problems caused by improper operation.



Split-type Flexible Rogowski Coil with Rail-Mounted 1A Integrator

Split-type Flexible Rogowski Coil With Integrator

Split-core Three-phase Flexible Rogowski Coil

Split-type Flexible Rogowski Coil Without Integrator